Current Conditions
11/29/2008 at 4:30 PM
Tank Temp : 78.1
Tank pH : 8.32
Tank ORP : 260
Sump Temp : 78.3
Calcium Reactor Effluent pH : 6.0
Calcium Reactor 2nd Chamber pH : 7.5

 

AC3 Timers/ Program

ALM&-A08     Alarm

OVF&-B11     Overflow

LW1&-B12    Low Water In Sump

LW2&-B16    Low Water 2 in Sump

HWS&-B13    High Water in Sump

LPR&-B14     Low Pressure Return Pump

LPC&-B15     Low Pressure Close L Pump

TM2$-P01    Temp sump #2

MHL$-A01   Metal Halide Light

CO2$-A02    Co2 For C.R Valve

RET#-A03    Return Pump

HET#-A04    Heater

COL%-A05    Cooler Pump

KLK%-A06    Kalk Reactor

OZN&-A07    Ozone Generator

ACT&-C01    Actinic Lights

REF&-C02    Refugim Light

SKI&-C03     Skimmer

UVA&-C04    UV Light

COP&-C06    Calcium Reactor Rec Pump

DAY&-C09    Day Timer

WTO&-C07   Water Top Off

MIX&-C08    Mixer

TUZ&-E01    Tunze Pump

Program

If Power 000        Then ALM ON

If Sun  000/000      Then MHL ON

If Sun  -090/090      Then ACT ON

If Sun  000/000      Then REF OFF

 

If Time > 00:00       Then RET ON

If Time > 00:00       Then KLK ON

If Time > 00:00       Then SKI ON

If Time > 00:00       Then COP ON

If Time > 00:00       Then WTO ON

If Time > 00:00       Then TUZ ON

 Cooler/Heater For Tank Temp

If Temp  > 81.5      Then MHL OFF

If Temp  > 77.7      Then COL ON

If Temp  < 77.4      Then COL OFF

If Temp  < 77.0      Then HET ON

If Temp  > 77.3      Then HET OFF

If Temp  > 79.9      Then ALM ON

If Temp  < 76.0      Then ALM ON

 Cooler/Heater For Sump Temp

If TmpA  > 77.7      Then COL ON

If TmpA  < 77.4      Then COL OFF

If TmpA  < 77.0      Then HET ON

If TmpA  > 77.3      Then HET OFF

If TmpA  < 76.0      Then ALM ON

If TmpA  > 79.9      Then ALM ON

 PH & Kalk  For Tank

If pH    > 08.25       Then KLK OFF

If pH    < 05.90       Then COP OFF

If pH    < 07.90       Then ALM ON

If pH    > 08.38       Then ALM ON

 PH For Calcium Reactor

If pHA1  < 06.10       Then CO2 OFF

If pHA1  > 06.20       Then CO2 ON

If pHA1  > 06.40       Then ALM ON

If pHA1  < 05.90       Then ALM ON

If pHA1  < 05.80       Then COP OFF

ORP & Ozone

If ORP   < 370         Then OZN ON

If ORP   > 400         Then OZN OFF

If ORP   > 550         Then ALM ON

If ORP   < 001         Then ALM ON

Kalk Mixer

OSC 005/235 ON/OFF    Then MIX OFF

If Timer MIX = ON       Then WTO OFF

Max Change 030 M      Then WTO OFF

Tunze Program

If Time > 09:00       Then DAY ON

If Time > 02:00       Then DAY OFF

If Timer DAY = ON       Then TUZ PF1

If Timer DAY = OFF        Then TUZ PF2

Pmp MODE SD     for PF1

Pmp Int 030/100     for PF1

Pmp OSC 12/12/05     for PF1

Pmp MODE sD     for PF2

Pmp Int 030/050     for PF2

Pmp OSC 20/20/00     for PF2

If Overflowà Stops Pump And Skimmer

If Timer OVF = ON       Then WTO OFF

If Timer OVF = ON       Then RET OFF

If Timer OVF = ON       Then SKI OFF

If Timer RET = OFF        Then SKI OFF

Alarm To confirm That System Work

If Time > 10:00       Then ALM ON

If Time > 10:02       Then ALM OFF

If Time > 15:00       Then ALM ON

If Time > 15:02       Then ALM OFF

If Time > 22:00       Then ALM ON

If Time > 22:02       Then ALM OFF

All Alarms

If SwitchA2 OPEN       Then LW1 OFF

If SwitchA2 CLOSED     Then LW1 ON

If SwitchA2 CLOSED     Then ALM ON

 

If Switch1  OPEN       Then TM2 OFF

If Switch1  CLOSED     Then TM2 ON

If Switch1  CLOSED     Then ALM ON

 

If SwitchA1 CLOSED     Then SKI OFF

If SwitchA1 CLOSED     Then RET OFF

Max Change 003 M      Then RET OFF

 

If SwitchA2 OPEN       Then OVF OFF

If SwitchA2 CLOSED     Then OVF ON

If SwitchA2 CLOSED     Then ALM ON

 

If SwitchA3 OPEN       Then HWS OFF

If SwitchA3 CLOSED     Then HWS ON

If SwitchA3 CLOSED     Then ALM ON

 

If SwitchA4 OPEN       Then LPR OFF

If SwitchA4 CLOSED     Then LPR ON

If SwitchA4 CLOSED     Then ALM ON

 

If SwitchA5 OPEN       Then LPC OFF

If SwitchA5 CLOSED     Then LPC ON

If SwitchA5 CLOSED     Then ALM ON

 

If SwitchA6 OPEN       Then LW2 OFF

If SwitchA6 CLOSED     Then LW2 ON

If SwitchA6 CLOSED     Then ALM ON

 Feed Aà  Fish Feeding

If FeedA 000         Then RET OFF

If FeedA 000         Then TUZ OFF

If FeedA 003         Then ALM OFF

If FeedA 000         Then COL OFF

If FeedA 030         Then SKI OFF

If FeedA 010        Then WTO OFF

Feed BàWater Change

If FeedB 000         Then RET OFF

If FeedB 000         Then SKI OFF

If FeedB 000         Then COL OFF

If FeedB 010         Then ALM OFF

If FeedB 000         Then HET OFF

If FeedB 020         Then WTO OFF

If FeedA 000         Then TUZ OFF

Feed C à Kalk Mixer-Manual

If FeedC 010         Then MIX ON

Feed D à Coral Feeding

If FeedD 005         Then TUZ OFF

If FeedD 000         Then SKI OFF

If FeedD 020         Then WTO OFF

 

 

 

 

 

 

This is The brain of the tank. Its control all the parameters as you can see in the program.  I can Run The Tank Few Weeks Without Touching It (If everything Is O.K)

 

 

 

 

 

.

 

 

 

 

 

 

 

 

This is the PX-1000. It’s give me the option For Additional PH and Temp as well as 6 more input to the units and as you can see, all of them are for alarms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This Is The DC-8. It’s get The commands From The AC3 And send Them To The Units

 

 

 

 

 

 

 

 

 

 

 

 

This Is The “Aquaserf” That Control The Tunze Via The AC3.

 

 

 

.

 

 

 

 

 

 

 

This is a DIY of IO Breakout Box. All the inputs from the float Switch Are Connected to This Box And Very Easy To Handle

 

 

 

 

 

 

 

 

 

 

 

 

Since I Have 7 Inputs For Alarms, I Built A box with Relays That Will Tell Me Which Alarm Coming On, And I marked Every Alarm. The AC3 Get only One Input To The unit So This Was The Only Way To Do So.

 

 

 

 

 

 

 

 

 

 

Every Alarm Is Send To Me Via Email And SMS And I Can Identify Each Alarm By The Switch Closed That Send To My Mail.

     

 

 

 

 

 

 

 

This Is the Schematic for the Relay

Connection and for Individual Sensor.

 

 

 

 

 

 

 

 

 

 

 

 

 

A Junction Box That I Built For Few More Relayes,24v And 12v  (For The Valves)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This is The Kalk Water Into the Sump. Its Comes Directly From The RODI Filters. Its work With Relay So When The PH is Too High The Relay Opens The Valve To Clear Water Into The Sump. If The PH Is O.k. The water goes Throw The Valve Into The  Kalk Reactor And Then To The Sump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

For the units That Are Not So Crucial I am Using The X-10. All Them Are On The same Phase.  This Are Only Few Of Them.

 

 

 

 

 

 

 

 

 

RODI Water Are Enter Into The Sump Directly From The RO filter And going Either Via The Kalk Reactor Or Bypass It According to PH .This Is The Auto Top To The Sump. Its Connect to the AC3 And I Also Have a Manuel Switch So I Can stops It, For Maintenance And Water Chang. There Is also a Light That goes On When It’s activated.

 

 

 

 

 

 

 

This is Additional Temp Control That located in the Sump. Its control Only Alert to email And SMS For The Temp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 